{"product_id":"up5000-coagulation-analyzer","title":"UP5000 coagulation analyzer","description":"\u003cdiv class=\"ys-nyban-title\"\u003e\n\u003cp\u003eThe classic optical detection principle, multi-wavelength light source design, and uninterrupted sample\/cuvette adding, empowering accurate and rapid clinical diagnosis and treatment.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ys-nyban-cry-cont\"\u003e\n\u003cul class=\"prod-cry-ul\"\u003e\n\u003cli class=\"prod-cry-ul-li wow ys-fadeup1\"\u003e\n\u003cdiv class=\"pcul-ri\"\u003e\n\u003cdiv class=\"pcul-ri-tit std-h2\"\u003eRational Management System\u003c\/div\u003e\n\u003cul class=\"pcul-ri-ul\"\u003e\n\u003cli class=\"pcul-ri-ul-li\"\u003e\n\u003cdiv class=\"prul-tit\"\u003e\n\u003cp class=\"std-h5\"\u003eReagent Management System\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"prul-text std-text1\"\u003e\n\u003cp\u003e28 reagent positions with refrigeration function, 4 diluent positions, 1 rinse station, Reagent position tilt design\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli class=\"pcul-ri-ul-li\"\u003e\n\u003cdiv class=\"prul-tit\"\u003e\n\u003cp class=\"std-h5\"\u003eSample Management System\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"prul-text std-text1\"\u003e\n\u003cp\u003e100 sample positions; continuous loading and automatic injection\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"prul-tit\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli class=\"pcul-ri-ul-li\"\u003e\n\u003cdiv class=\"prul-tit\"\u003e\n\u003cp class=\"std-h5\"\u003eSample Adding Management System\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"prul-text std-text1\"\u003e\n\u003cp\u003eTwo reagent probes and 1 sample probe add reagents independently\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"prul-tit\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli class=\"pcul-ri-ul-li\"\u003e\n\u003cdiv class=\"prul-tit\"\u003e\n\u003cp class=\"std-h5\"\u003eMeasurement Management System\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"prul-text std-text1\"\u003e\n\u003cp\u003eLED light source, With 20 full-wavelength detection channels for coagulation, immunoturbidimetry, chromogenic substrate assay, Multi-wavelength (405nm\/570nm\/660nm\/800nm) design, realize HlL intelligent anti-interference\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"prul-tit\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli class=\"pcul-ri-ul-li\"\u003e\n\u003cdiv class=\"prul-tit\"\u003e\n\u003cp class=\"std-h5\"\u003eAutomatic Cuvette Selection and Transmission System\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"prul-text std-text1\"\u003e\n\u003cp\u003e2000 cuvettes capacity with continuous loading, Selection mechanism automatically selects and transmits them to the reagent position, Missing cuvette alarm function\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"prul-tit\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli class=\"pcul-ri-ul-li\"\u003e\n\u003cdiv class=\"prul-tit\"\u003e\n\u003cp class=\"std-h5\"\u003eBarcode Management System\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"prul-text std-text1\"\u003e\n\u003cp\u003eAutomatically sample barcode reading, Automatically reagent barcode reading, Managing reagent and material reasonably\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"prul-tit\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli class=\"prod-cry-ul-li wow ys-fadeup1\"\u003e\n\u003cdiv class=\"pcul-le ys-imgbox-cover\"\u003e\n\u003cimg src=\"https:\/\/www.sunbiote.com\/Public\/En\/images\/ada_06.png\" alt=\"\"\u003e\u003cimg src=\"https:\/\/www.sunbiote.com\/Public\/Uploads\/uploadfile\/images\/20241228\/up50001.jpg\" alt=\"up50001.jpg\"\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pcul-ri\"\u003e\n\u003cdiv class=\"pcul-ri-tit std-h2\"\u003eDiverse Test Principles\u003c\/div\u003e\n\u003cul class=\"pcul-ri-ul\"\u003e\n\u003cli class=\"pcul-ri-ul-li\"\u003e\n\u003cdiv class=\"prul-tit\"\u003e\n\u003cp class=\"std-h5\"\u003eCoagulation Method\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"prul-text std-text1\"\u003e\n\u003cp\u003ePT, APTT, TT, FlB, APCR, LA1, LA2, PS...\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli class=\"pcul-ri-ul-li\"\u003e\n\u003cdiv class=\"prul-tit\"\u003e\n\u003cp class=\"std-h5\"\u003eImmunoturbidimetric Assay\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"prul-text std-text1\"\u003e\n\u003cp\u003eD-Dimer, FDP, VWF...\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"prul-tit\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli class=\"pcul-ri-ul-li\"\u003e\n\u003cdiv class=\"prul-tit\"\u003e\n\u003cp class=\"std-h5\"\u003eChromogenic Substrate Assay\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"prul-text std-text1\"\u003e\n\u003cp\u003eAT-III, PC, HEP, PLG, Anti-Xa...\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"prul-tit\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli class=\"prod-cry-ul-li wow ys-fadeup1\"\u003e\n\u003cdiv class=\"pcul-le ys-imgbox-cover\"\u003e\n\u003cimg src=\"https:\/\/www.sunbiote.com\/Public\/En\/images\/ada_06.png\" alt=\"\"\u003e\u003cimg src=\"https:\/\/www.sunbiote.com\/Public\/Uploads\/uploadfile\/images\/20241228\/up50002.jpg\" alt=\"up50002.jpg\"\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pcul-ri\"\u003e\n\u003cdiv class=\"pcul-ri-tit std-h2\"\u003eMore Efficient and Stable Performance\u003c\/div\u003e\n\u003cul class=\"pcul-ri-ul\"\u003e\n\u003cli class=\"pcul-ri-ul-li\"\u003e\n\u003cdiv class=\"prul-tit\"\u003e\n\u003cp class=\"std-h5\"\u003eVarieties of standard curve plotting\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli class=\"pcul-ri-ul-li\"\u003e\n\u003cdiv class=\"prul-tit\"\u003e\n\u003cp class=\"std-h5\"\u003ePT\/APTT\/TT\/FlB\/D-Dimer throughput 420 Ts\/H\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli class=\"pcul-ri-ul-li\"\u003e\n\u003cdiv class=\"prul-tit\"\u003e\n\u003cp class=\"std-h5\"\u003e32 independent incubation positions for batch pre-warming\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli class=\"pcul-ri-ul-li\"\u003e\n\u003cdiv class=\"prul-tit\"\u003e\n\u003cp class=\"std-h5\"\u003eExcellent repeatable, accurate and linear test result\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli class=\"pcul-ri-ul-li\"\u003e\n\u003cdiv class=\"prul-tit\"\u003e\n\u003cp class=\"std-h5\"\u003eReliable auto-retest function\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli class=\"pcul-ri-ul-li\"\u003e\n\u003cdiv class=\"prul-tit\"\u003e\n\u003cp class=\"std-h5\"\u003eAutomatic APTT mixing study\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli class=\"pcul-ri-ul-li\"\u003e\n\u003cdiv class=\"prul-tit\"\u003e\n\u003cp class=\"std-h5\"\u003eMeet emergency and outpatient service requirements by STAT function\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli class=\"prod-cry-ul-li wow ys-fadeup1\"\u003e\n\u003cdiv class=\"pcul-le ys-imgbox-cover\"\u003e\n\u003cimg src=\"https:\/\/www.sunbiote.com\/Public\/En\/images\/ada_06.png\" alt=\"\"\u003e\u003cimg src=\"https:\/\/www.sunbiote.com\/Public\/Uploads\/uploadfile\/images\/20241228\/up50003.jpg\" alt=\"up50003.jpg\"\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pcul-ri\"\u003e\n\u003cdiv class=\"pcul-ri-tit std-h2\"\u003eHumanized Operation System\u003c\/div\u003e\n\u003cul class=\"pcul-ri-ul\"\u003e\n\u003cli class=\"pcul-ri-ul-li\"\u003e\n\u003cdiv class=\"prul-tit\"\u003e\n\u003cp class=\"std-h5\"\u003eSecure and stable Windows OS, with Chinese\/English language interface\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli class=\"pcul-ri-ul-li\"\u003e\n\u003cdiv class=\"prul-tit\"\u003e\n\u003cp class=\"std-h5\"\u003eSuper data storage capacity\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"prul-tit\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli class=\"pcul-ri-ul-li\"\u003e\n\u003cdiv class=\"prul-tit\"\u003e\n\u003cp class=\"std-h5\"\u003eAutomatic dilution, calibration and screening analysis, Alarm function with real-time reflecting malfunction\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"prod-cry-para wow ys-fadeup1\"\u003e\n\u003ch2 class=\"std-h2\"\u003eInstrument parameters\u003c\/h2\u003e\n\u003cdiv class=\"prod-cry-para-cry\"\u003e\n\u003cdiv class=\"pcpc-le\"\u003e\n\u003cdiv class=\"pcpc-le-img\"\u003e\u003cimg src=\"https:\/\/www.sunbiote.com\/Public\/Uploads\/uploadfile\/images\/20241230\/50001-8.png\" alt=\"5000-1.png\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pcpc-ri\"\u003e\n\u003cul class=\"pcpc-ri-ul\"\u003e\n\u003cli class=\"pcpc-ri-ul-li\"\u003e\n\u003cdiv class=\"prul-le std-text1\"\u003ePrinciple\u003c\/div\u003e\n\u003cdiv class=\"prul-ri std-text1\"\u003eOptical\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli class=\"pcpc-ri-ul-li\"\u003e\n\u003cdiv class=\"prul-le std-text1\"\u003eData storage\u003c\/div\u003e\n\u003cdiv class=\"prul-ri std-text1\"\u003e100000 sample results and reaction curves\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli class=\"pcpc-ri-ul-li\"\u003e\n\u003cdiv class=\"prul-le std-text1\"\u003eLanguage\u003c\/div\u003e\n\u003cdiv class=\"prul-ri std-text1\"\u003eChinese English\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli class=\"pcpc-ri-ul-li\"\u003e\n\u003cdiv class=\"prul-le std-text1\"\u003eReport formats\u003c\/div\u003e\n\u003cdiv class=\"prul-ri std-text1\"\u003eMultiple forms of report output can be supported\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli class=\"pcpc-ri-ul-li\"\u003e\n\u003cdiv class=\"prul-le std-text1\"\u003eOperating environment\u003c\/div\u003e\n\u003cdiv class=\"prul-ri std-text1\"\u003e10℃～30℃，relative humidity ≤80%\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli class=\"pcpc-ri-ul-li\"\u003e\n\u003cdiv class=\"prul-le std-text1\"\u003eStorage environment\u003c\/div\u003e\n\u003cdiv class=\"prul-ri std-text1\"\u003e-20℃～55℃，relative humidity≤85%\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"BIOGENE","offers":[{"title":"Default Title","offer_id":51656889270555,"sku":null,"price":0.0,"currency_code":"TND","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0993\/3062\/1723\/files\/5000xinyiqi111kaobei.png?v=1769037676","url":"https:\/\/biogenetunisie.com\/products\/up5000-coagulation-analyzer","provider":"BIOGENE","version":"1.0","type":"link"}